Skip to main content
Account

Table 5 MHF of water and functionalized nanofluid

From: Application of functionalized nanofluid in thermosyphon

 

Water

Functionalized nanofluid (1.5 wt.%)

Operating temperature (°C)

MHF (W/m2/k)

Deviation of equation 8

Deviation of equation 9

MHF (W/m2/k)

Deviation of equation 9

70

160,863

12.7%

-9.3%

154,602

6.5%

55

128,738

13.0%

-7.7%

124,168

6.8%

40

108,582

2.6%

-12.6%

104,576

-2.6%

Navigation