Skip to main content

Table 5 MHF of water and functionalized nanofluid

From: Application of functionalized nanofluid in thermosyphon

  Water Functionalized nanofluid (1.5 wt.%)
Operating temperature (°C) MHF (W/m2/k) Deviation of equation 8 Deviation of equation 9 MHF (W/m2/k) Deviation of equation 9
70 160,863 12.7% -9.3% 154,602 6.5%
55 128,738 13.0% -7.7% 124,168 6.8%
40 108,582 2.6% -12.6% 104,576 -2.6%