Figure 1From: Negative pressure characteristics of an evaporating meniscus at nanoscale Liquid argon meniscus, surrounded by argon vapor, in an opening constructed of platinum wall atoms. (a) 2D view along the x-z plane depicting the boundary conditions and dimensions, and (b) 3D view of the simulation domain where the liquid-vapor interface can be clearly noticeable. Heat is transferred to the meniscus from the platinum wall region shown in red, while the region shown in blue is maintained at the lower initial temperature.Back to article page