Table 5 Comparison of MD simulation results with the literature

From: Effects of water molecules on tribological behavior and property measurements in nano-indentation processes - a numerical analysis

 

Hardness (GPa)

Young's modulus (GPa)

Case 1 of this study - wet indentation

19.5 to 25.5

194.1

Case 2 of this study - dry indentation

12.7 to 21.7

255.3

MD simulation by Fang et al. [37]

20.4 to 43.4

283.4 to 444.9

MD simulation by Leng et al. [38]

23

N/A

Nano-indentation experiment [36]

7.1 to 10

135

Micro-indentation experiment

2.1 [39]

116 to 126 [40]