Skip to main content
Account

Table 5 Measurement uncertainty for relevant parameters/variables

From: Spray cooling characteristics of nanofluids for electronic power devices

Parameters/variables

System error

Random error

Combined error

Test surface

Length (L)

±0.05%

±0.94%

±0.94%

Width (W)

±0.05%

±0.88%

±0.88%

High (H)

±0.5%

±4.58%

±4.61%

Area (A)

±0.1%

±1.82%

±1.82%

Test chamber

Length (L)

±0.02%

±1.05%

±1.05%

Width (W)

±0.02%

±1.27%

±1.27%

High (H)

±0.04%

±3.20%

±3.2%

Distance between thermocouples (Δx)

±0.2%

±1.17%

±1.19%

Measurement parameters and variables

Surface temperature (Tw)

±3.87%

±7.40%

±8.35%

Power (P)

±1.91%

±3.02%

±3.57%

Heat flux (q″)

±2.01%

±4.84%

±5.24%

Volumetric flow rate (Q)

±1.60%

±2.74%

±3.17%

Mass flux (G)

±1.70%

±4.56%

±4.87%

Pressure drop (ΔP)

±0.18%

±1.42%

±1.43%

Dimensionless group/heat transfer data

Weber number (We)

±1.33%

±2.58%

±2.9%

Reynolds number (Re)

±1.72%

±5.03%

±5.32%

Heat transfer coefficient (h)

±5.88%

±12.24%

±13.58%