Table 1 Electrical parameters of OPV leaf modules (with separate areas I–III) illuminated under 1 sun (AM 1.5)
From: Custom-Shaped Organic Photovoltaic Modules—Freedom of Design by Printing
OPV leaf | Leaf area | Active area [mm2] | Isc [mA] | Voc [V] | Voc/cell [V] | FF [%] | PCE [%] | Pmax [mW] |
---|---|---|---|---|---|---|---|---|
Leaf 1 | Area I | 748 | 5.6 | 4.7 | 0.59 | 53 | 1.9 | 14 |
Area II | 2180 | 16 | 4.7 | 0.59 | 52 | 1.9 | 40 | |
Area III | 2180 | 17 | 4.7 | 0.58 | 47 | 1.7 | 38 | |
Leaf 2 | Area I | 748 | 5.9 | 4.6 | 0.58 | 52 | 1.9 | 14 |
Area II | 2180 | 17 | 4.7 | 0.59 | 53 | 2.0 | 43 | |
Area III | 2180 | 18 | 4.7 | 0.58 | 45 | 1.7 | 37 | |
Leaf 3 | Area I | 748 | 6.0 | 4.7 | 0.59 | 52 | 2.0 | 15 |
Area II | 2180 | 17 | 4.7 | 0.59 | 56 | 2.0 | 44 | |
Area III | 2180 | 15 | 4.7 | 0.59 | 40 | 1.3 | 28 | |
Leaf 4 | Area I | 748 | 5.8 | 4.5 | 0.57 | 49 | 1.7 | 13 |
Area II | 2180 | 18 | 4.6 | 0.58 | 51 | 2.0 | 43 | |
Area III | 2180 | 17 | 4.7 | 0.58 | 53 | 1.9 | 42 |