Table 1 The electrochemical performance of PCBs based on SnS2/β-CD/SPCE compared with previous reports
Modified electrode | Linear range (nM/L) | LOD (nM/L) | Ref |
---|---|---|---|
Antibody-immobilize on conducting polymer | 1.1 to 3.8 × 102 | a1.3 × 101, b5.3, c1.2, and d6.4 | [24] |
Screen-printed electrochemical immunosensor | 0.1 to 10 | 7 × 10−3 | [25] |
Functionalized magnetic beads and carbon based screen-printed carbon electrodes | – | a1.1, b1.4, c1.5, and d3.1 | [26] |
Food samples (sheep milk, bovine adipose tissue, and bovine muscle) | f3.6 × 101 to 1.8 × 105 | e3.6 × 101 | [2] |
Antibody coated magnetic beads | – | e3.6 × 101 and f3.9 | [27] |
Label-free impedimetric immunoassay | h3.3 × 10−2 3.3 × 101 | g3.3 × 10−3 | [28] |
Direct competitive enzyme-linked immunosorbent assay | d3.1 × 10−2 to 4.6 | c3 × 10−2 | [29] |
Silver nanoparticles doped polyaniline modified glassy carbon electrode | g7.8 × 10−1 and 4.6 | f2.4 × 10−1 | [30] |
SnS2/β-CD modified screen-printed electrode | 625 to 8 × 104 | 5 × 103 | This work |