Table 1 Summary of CHF results (uncertainty ± 10%)
From: Infrared thermometry study of nanofluid pool boiling phenomena
Test fluid | Expt. no. | Critical heat flux value (kW/m2) | Average critical heat flux value for test fluid (kW/m2) |
---|---|---|---|
DI water | 1 | 900 | 976 |
2 | 1,080 | ||
3 | 900 | ||
4 | 1,000 | ||
5 | 1,000 | ||
Nanofluid-Silica (0.1 vol.%) in water | 1 | 1,800 | 1,767 |
2 | 1,900 | ||
3 | 1,600 | ||
Nanofluid-Diamond (0.01 vol.%) in water | 1 | 2,000 | 1,950 |
2 | 1,900 |