Table 4 Standard deviation of the various correlations with respect to experimental results
From: Boiling local heat transfer enhancement in minichannels using nanofluids
G value (kg/m2) | Measurement results | Warrier et al.[27] (%) | Kandlikar and Balasubramanian[28] (%) | Sun and Mishima[29] (%) | Bertsch et al.[30] (%) | Lazarek and Black[31] (%) | Gungor and Winterton[32] (%) | Liu and Witerton[36] (%) | Kew and Cornwell[33] (%) | Yan and Lin[34] (%) |
---|---|---|---|---|---|---|---|---|---|---|
130.59 | 0.92 | −27.89 | 41.6 | 133.99 | 166.33 | 65.87 | 188.31 | −32.68 | 16.22 | −19.64 |
174.12 | 1.24 | −31.37 | 30.34 | 97.03 | 130.45 | 60.27 | 93.15 | −60.02 | 33.67 | −8.55 |
217.65 | 1.63 | −34.92 | 20.25 | 80.65 | 100.28 | 45.09 | 67.84 | −43.69 | −1.22 | −6.23 |
261.18 | 2.12 | −38.41 | 10.32 | 48.89 | 44.37 | 25.75 | 16.35 | −58.02 | −18.09 | −26.22 |
304.71 | 2.37 | −36.85 | 10.14 | 50.32 | 53.31 | 29.29 | 8.49 | −56.62 | −20.13 | −22.64 |
348.24 | 2.96 | −40.13 | 0.84 | 25.01 | 30.2 | 11.31 | −10.39 | −59.7 | −25.52 | −25.17 |
391.77 | 3.2 | −38.46 | 1.54 | 28.33 | 60.69 | 14.79 | 2.17 | −47.7 | −17.36 | −5.16 |
435.3 | 3.39 | −33.23 | 6.6 | 26.66 | 69.24 | 27.36 | 4.72 | −42.28 | −14.41 | 11.49 |
478.83 | 3.95 | −35.52 | −0.32 | 13.33 | 60.17 | 3.62 | −3.11 | −43.35 | −20.11 | 14.45 |
522.36 | 4.2 | −31.93 | 2.24 | 6.52 | 38.53 | 17.09 | −19.72 | −52.51 | −26.04 | 4.7 |
565.89 | 4.48 | −29.01 | 2.21 | 3.02 | 47.22 | −0.97 | −16.04 | −47.65 | −25.47 | 22.78 |
609.42 | 5.06 | −29.69 | −0.56 | −5.43 | 41.32 | 5.61 | −19.94 | −48.04 | −29.81 | 25.42 |
652.95 | 5.55 | −29.21 | −7.08 | −10.67 | 53.45 | 12.48 | 5.53 | −36.92 | −28.05 | 29.41 |