Skip to main content
Account

Table 1 Summarized results for thermal diffusivity ratio of Ag nanofluids with varying MW irradiation time for two solvents DW and EG

From: Fabrication, characterization, and thermal property evaluation of silver nanofluids

 

Water

Ethylene glycol

Time (s)

Thermal diffusivity(cm2/s) × 10−3

Thermal diffusivity ratio (αsamplebase fluid)

Thermal diffusivity (cm2/s) × 10−3

Thermal diffusivity ratio (αsamplebase fluid)

20

1.476 ± 0.022

1.02

0.969 ± 0.009

1.04

40

1.532 ± 0.011

1.06

1.036 ± 0.011

1.12

60

1.624 ± 0.021

1.13

1.101 ± 0.006

1.19

90

1.729 ± 0.032

1.20

1.158 ± 0.007

1.25