Table 1 Photophysical data for CDs (3.75 μg mL−1 in deionized water) before and after 0.5 M H2O2 treatment
From: Carbon Nanodots as Dual-Mode Nanosensors for Selective Detection of Hydrogen Peroxide
States | λ em a (nm) | τ b (ns) | χ 2c | QYd (%) |
---|---|---|---|---|
Before | 450 | 7.96 | 0.999 | 5.5 |
Before | 500 | 7.12 | 0.999 | |
After | 450 | 4.53 | 0.993 | 4.6 |
After | 500 | 4.83 | 0.996 |