Table 1 Comparison of the linear ranges and detection limits towards 4-NP for various literature methods
Method | Linear range (μg mL− 1) | Detection limit (ng mL−1) | Ref. |
---|---|---|---|
Cu2O NP-modified Pt rotating ring-disk electrode | 1.39–139 | 13.9 | [50] |
Carbon nanotube film electrode | 0.14–4.86 | 16.7 | [51] |
Graphene–Au composite chemical sensor | 0.065–1.5 | 65 | [52] |
Hydroxyapatite nanopowder-modified glassy carbon electrode | 0.14–4.17 | 83 | [53] |
Functionalized mesoporous silica fluorescent sensor | 0.5–1.25 | 101 | [54] |
MIP-coated GQD fluorescent sensor | 0.02–3.00 | 9.00 | [9] |
Fe3O4 nanoparticle-CdTe quantum dot-MIP composite | 1.391–8.346 | 34.8 | [55] |
MIP-capped CdTe QDs | 0.139–4.17 | 5.6 | [56] |
CDs-YVO4:Eu3+@MIPs | 0–1.67 | 20.85 | [10] |
CdSe@SiO2/CD/MIP nanohybrid | 0.051–13.7 | 26 | This work |