Skip to main content
Account

Table 1 Comparison of the linear ranges and detection limits towards 4-NP for various literature methods

From: Molecularly Imprinted Core-Shell CdSe@SiO2/CDs as a Ratiometric Fluorescent Probe for 4-Nitrophenol Sensing

Method

Linear range (μg mL− 1)

Detection limit (ng mL−1)

Ref.

Cu2O NP-modified Pt rotating ring-disk electrode

1.39–139

13.9

[50]

Carbon nanotube film electrode

0.14–4.86

16.7

[51]

Graphene–Au composite chemical sensor

0.065–1.5

65

[52]

Hydroxyapatite nanopowder-modified glassy carbon electrode

0.14–4.17

83

[53]

Functionalized mesoporous silica fluorescent sensor

0.5–1.25

101

[54]

MIP-coated GQD fluorescent sensor

0.02–3.00

9.00

[9]

Fe3O4 nanoparticle-CdTe quantum dot-MIP composite

1.391–8.346

34.8

[55]

MIP-capped CdTe QDs

0.139–4.17

5.6

[56]

CDs-YVO4:Eu3+@MIPs

0–1.67

20.85

[10]

CdSe@SiO2/CD/MIP nanohybrid

0.051–13.7

26

This work

Navigation