Skip to main content
Account

Table 1 Short-circuit densities as calculated from EQE and JV measurements are in good agreement

From: Improved Metal Oxide Electrode for CIGS Solar Cells: The Application of an AgOX Wetting Layer

Ag thickness (nm)

OMO JSC (mA/cm2)

OWLMO JSC (mA/cm2)

JV curve

EQE

JV curve

EQE

6

28.81

28.44

33.90

34.14

7

28.58

29.03

32.91

32.60

8

28.24

28.89

32.05

32.51

Navigation