Skip to main content
Account

Table 3 Copper removal efficiency under different dosages (0.05–0.08 g) The letters difference a-g indicate the level of significant differences in copper removal efficiencies at varied dosage (p<0.0001).

From: Adsorptive Removal of Copper (II) Ions from Aqueous Solution Using a Magnetite Nano-Adsorbent from Mill Scale Waste: Synthesis, Characterization, Adsorption and Kinetic Modelling Studies

Time

Dosage

0.05 g

0.2 g

0.5 g

0.8 g

0

0.00f

0.00f

0.00 g

0.00 g

5

17.67e

30.56d

7.15f

7.03f

15

43.18d

31.27c

11.34e

8.46e

30

49.30c

36.52b

14.31d

10.07d

60

55.10b

37.27a

21.82c

11.56c

120

62.58a

37.44a

38.73b

13.26b

180

62.61a

37.43a

40.43a

24.31a

240

62.62a

37.23a

40.29a

24.30a

p value

 < .0001

 < .0001

 < .0001

 < .0001

  1. The letters indicate the level of significant and differences in the removal efficiencies of Cu2+